The Measurements Explorer allows to view the measurements stored in the channels of an active Data Set of the selected Test Setup.  

By default only some of the channels are shown. The default number is set in the Preference Dialog. The selected channels are indicated in the Data Organizer by a small check mark. Here you can check/uncheck the channels you wish to see in the Measurements Explorer.

Zooming and Creation of New Data Sets

For viewing the measurements one can zoom in and out using the zoom bar in the bottom of the Measurements Explorer.

One can create a new Data Set using e.g. a portion of the original measurements by zooming in and clicking the toolbar button . This will start the Edit Time Series Data dialog.

Edit Time Series Data dialog

The dialog shows the selected interval. One can modify it via Start and Stop fields of the Range Selection. When saving the selected range, the Destination Data Set list specifies whether to overwrite the currently selected Data Set or to create a new one. When saving the selected measurements there are several pre-processing options available:

In case of the integration it is necessary to filter the data with a high pass filter having a cut-off frequency close to 0 Hz. This is necessary to remove the integration error that will happen at DC. The filter can be modified from its default value by clicking the Integration Settings button.

Measurements Explorer Properties

The Measurements Explorer allows to toggle simple statistical characteristics of each channel by clicking on the Measurement Explorer window. By default, the Median Statistics are disabled. They can be enabled through the preferences window.